beautypg.com

RISCO Group LightSYS 2 User Manual

Page 109

background image

Installer Programming

Page 109

Quick Keys

Parameter

Default

Range

ZZ

Auxiliary Relay Mode  

Off

 

Defines the operation of the auxiliary relay of the detector. 

OFF

 ‐ Auxiliary relay is disabled  

24 Hours ‐ The auxiliary relay will always follow an alarm 
 NIGHT ONLY ‐ The auxiliary relay output will follow an alarm 
condition only during night time. The time defined by the photocell on 
the PCB. 

ZZ

Auxiliary Relay Time  

2.2 Seconds                      2.2–480 seconds

 

Defines the time duration that the auxiliary relay is activated. 
 2.2 SECONDS  2 MINUTES 4 MINUTES  8 MINUTES

Bus Zone: iWISE DT Grade 2

Quick Keys

Parameter

Default

Range

ZZ

LEDS                              

On

 

Defines the LEDS operation mode. 
OFF ‐ Disables the LEDS operation. 

ON

 – Enables the LEDS operation. 

ZZ

MW (Microwave) Range   

Trimmer

 

Defines the microwave channel range. 
MINIMUM 25% 50% 65%  85%  MAXIMUM  TRIMMER
(MW is defined by the trimmer setting on the PCB) 

ZZ

ACT                                  

No

 

Defines the Anti‐Cloak™ Technology (ACT) operation mode. 
NO – Disables the ACT mode 
 YES – Enables the ACT mode 

ZZ

Automatic Microwave Bypass  

 No

 

Defines whether the MW channel will be bypassed or not while the 
detector identifies trouble in the MW channel. 
NO ‐ While detecting a problem in the MW channel it is not bypassed. 
Alarm condition cannot be established until the MW channel is fixed. 
YES ‐ Switches the detector to operate only in PIR mode in case of 
MW trouble