Installer Programming

Page 110

Quick Keys

Parameter

Default

Range

ZZ

Green Line

                 

Yes

 

A feature that follows environmental guidelines by avoiding surplus 
emission This feature defines the activation of the microwave channel 
while the system is disarmed. 
NO ‐ Green Line feature is disabled. MW is constantly activated. 
YES ‐ Green Line feature is activated. 

ZZ

Self Test                      

Remote

 

Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created. 
REMOTE (Manual) ‐ The remote self test is performed by the system 
when a user manually selects the Diagnostics option from the 
Maintenance menu via the LightSYS2 User Functions menu 
LOCAL (automatic) ‐ Once an hour, the detector automatically checks 
that the detector’s channels are functioning properly. 

Bus Zone: (Industrial) Lunar /BWare/iWISE DT Grade 3

Quick Keys

Parameter

Default

Range

ZZ

LEDS                               

On

 

Defines the LEDS operation mode. 
OFF ‐ Disables the LEDS operation. 

ON

 – Enables the LEDS operation. 

ZZ

MW (Microwave) Range 

Trimmer

 

Defines the microwave channel range. 
MINIMUM 25% 50% 65%  85%  MAXIMUM  TRIMMER 
(MW is defined by the trimmer setting on the PCB) 

ZZ

ACT                                 

No

 

Defines the Anti‐Cloak™ Technology (ACT) operation mode.. 
NO – Disables the ACT mode 
 YES – Enables the ACT mode