RISCO Group LightSYS 2 User Manual
Page 88
Installer Programming
Page 88
System: Controls: CP-01
Quick Keys
Parameter
Default
Range
CP‐01
This section refers to controls that apply to comply with SIA CP 01.
Exit Restart
No
Yes/No
This parameter is used to define if an exit time shall restart one
additional time while an entry/exit zone is tripped twice during exit
time.
YES: Exit time will restart for one time only when an entry/exit zone is
tripped during exit time.
NO: Exit time will not be affected if an entry/exit zone is tripped during
exit time.
Auto Stay
No
Yes/No
This parameter is used to define the system’s arming mode when using a
keypad and no exit/entry zone is tripped during exit mode.
YES: If no exit/entry zone is tripped during exit time the system will be
armed in STAY mode.
NO: If no exit/entry zone is tripped during exit time the system will be
armed in Away mode.
System: Controls: Device
Quick Keys
Parameter
Default
Range
Device
Yes
Yes/No
This section refers to controls that apply BUS device
Anti Mask = Tamper
No
Yes/No
Used to determine the operation of Anti Masking detection in a bus
zone.
YES: Anti mask violation will activate tamper alarm.
NO: Anti mask violation will be regarded as trouble event.