RISCO Group LightSYS 2 User Manual
Page 163
Installer Programming
Page 163
Quick Keys
Parameter
Default
Range
1
st
Backup 3
rd
Call 2
nd
: Reports MS 1. If communication is not
established calls to MS 3. In addition it will also call MS 2.
2
nd
Backup 3
rd
Call 1
st
: Reports to MS 2. If communication is not
established calls MS 3. In addition it will also call MS 1
.
MS Urgent
1
st
backup 2
nd
Reports urgent (alarm) events to the Central Monitoring Station
Do not call (no report)
Send 1
st
: Reports Openings and Closings to MS 1.
Send 2
nd
: Reports Openings and Closings to MS 2.
Send 3
rd
: Reports Openings and Closings to MS 3.
Send all: Reports Openings and Closings to the all defined MS.
1
st
Backup 2
nd
: Reports Openings and Closings to MS 1. If
communication is not established, calls MS 2.
1
st
Backup 2
nd
3rd: Reports to MS 1. If communication is not
established calls MS 2. If communication is not established again calls the
MS.
1
st
Backup 3
rd
Call 2
nd
: Reports MS 1. If communication is not
established calls to MS 3. In addition it will also call MS 2.
2
nd
Backup 3
rd
Call 1
st
: Reports to MS 2. If communication is not
established calls MS 3. In addition it will also call MS 1
.
MS Non Urgent
Reports non‐urgent events (supervisory troubles and test reports) to the
MS
Do not call (no report)
Send 1
st
: Reports Openings and Closings to MS 1.
Send 2
nd
: Reports Openings and Closings to MS 2.
Send 3
rd
: Reports Openings and Closings to MS 3.
Send all: Reports Openings and Closings to the all defined MS.
1
st
Backup 2
nd
: Reports Openings and Closings to MS 1. If
communication is not established, calls MS 2.