RISCO Group LightSYS 2 User Manual
Page 137
Installer Programming
Page 137
Quick Keys
Parameter
Default
Range
Latch N/O
05 seconds
01‐90 seconds
The utility output is always deactivated (N/O) before it is triggered
(pulled up).
When triggered, it activates (is pulled down) and remains activated
(latched) until the operation is restored.
1. Press
and then press
.
2. Using the
key select ALL or ANY to set the activation and
press
.
3. Using the
key select ALL or ANY to set the deactivation
and press
.
4. Define the output label and press
Note
You can create and/or edit a ten‐character label description for each
utility output. See page 62, for additional details
Utility Output; Activation/Deactivation
When the utility output is following more than one partition or zone, the installer can choose
the logic of the utility output activation or deactivation, as follows:
If the Pattern of Operation is defined as Latch N/O or Latch N/C, the Installer can choose
the activation and deactivation logic of the UO to follow either after all the
Partitions/Zones or after any of the Partitions/Zones.
If the Pattern of Operation is defined as Pulse N/O or Pulse N/C, the Installer can choose
only the activation logic of the utility output to follow either after all the
Partitions/Zones or after any of the Partitions/Zones. The deactivation operation follows
the defined time period.
4 Codes
The Codes menu provides access to submenus and their related parameters that enable you
to maintain the User Codes in the system
In addition, the LightSYS2 contains the following special codes:
Grand Master Code: Used by the system’s owner or chief user.
Installer Code: Used by the LightSYS2 installation company technician to program the
main panel.