RISCO Group LightSYS 2 User Manual
Page 112

Installer Programming
Page 112
Bus Zone: iWISE QUAD Grade 2
Quick Keys
Parameter
Default
Range
ZZ
LEDS
On
Defines the LEDS operation mode.
OFF ‐ Disables the LEDS operation.
ON ‐ Enables the LEDS operation
ZZ
PIR Sensitivity
High
Defines the PIR sensitivity of the detector.
LOW HIGH
ZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created
REMOTE (Manual) ‐ The remote self test is performed by the system
when a user manually selects the Diagnostics option from the
Maintenance menu via the LightSYS2 User Functions menu
LOCAL (automatic) ‐ Once an hour, the detector automatically checks
that the detector’s channels are functioning properly
Bus Zone: iWISE/BWare QUAD Grade 3
Quick Keys
Parameter
Default
Range
ZZ
LEDS
On
Defines the LEDS operation mode.
OFF ‐ Disables the LEDS operation.
ON – Enables the LEDS operation.
ZZ
PIR Sensitivity
High
Defines the PIR sensitivity of the detector.
LOW HIGH
ZZ
Anti‐Mask
Enable
Defines the operation of Anti Masking detection.
DISABLE ENABLE and behaves according to the settings defined in
quick keys
ZZ