Page 89

Quick Keys

Parameter

Default

Range

 

 

Proximity  Anti Mask   
=Tamper
 

 No

  

Yes/No

 

Used to determine the operation of the proximity anti masking detection 
indicated by the MW channel in the WatchOUT DT detector. 
YES
: Proximity anti mask detection will activate the tamper alarm. 
NO
: Proximity anti mask detection will be regarded as a fault event. 
Note that Proximity AM operates for approximately 2.2 seconds when 
the detector is approached in close proximity. 
Ensure that Prox Anti Mask has been enabled when configuring the 
WatchOUT DT bus zone parameters. 

 

 

Audible Proximity Tamper

 No

  

Yes/No

 

This parameter relates to the bus siren. 
YES: A proximity anti approach violation will activate the siren. 
NO: A proximity anti approach violation will not activate the siren and 
will be regarded as trouble by the system. 

 

 

 

 

 

Siren Auxiliary = Tamper 

 No

  

Yes/No

 

This parameter relates to the bus siren. 
YES: A siren auxiliary trouble will be regarded as tamper alarm by the 
system. 
NO: A siren auxiliary trouble will be regarded as trouble by the system. 



RF Wake‐Up 

 No

 

 

Yes/No 

Determines whether the system can wake the 2‐way keypad up during 
exit/entry times or when failing to set the system. 
YES: The system wakes the keypad. 
NO: The system cannot wake up a 2‐way keypad. Use this option to save 
battery life.  



Keyfob Instant Arm 

 No

 

 

Yes/No 

YES: Away arming from any 2‐way remote control will be instant. 
NO: Away arming from any 2‐way remote control will be delayed, 
following exit delay 1.