Installer Programming
Page 89
Quick Keys
Parameter
Default
Range
Proximity Anti Mask
=Tamper
No
Yes/No
Used to determine the operation of the proximity anti masking detection
indicated by the MW channel in the WatchOUT DT detector.
YES: Proximity anti mask detection will activate the tamper alarm.
NO: Proximity anti mask detection will be regarded as a fault event.
Note that Proximity AM operates for approximately 2.2 seconds when
the detector is approached in close proximity.
Ensure that Prox Anti Mask has been enabled when configuring the
WatchOUT DT bus zone parameters.
Audible Proximity Tamper
No
Yes/No
This parameter relates to the bus siren.
YES: A proximity anti approach violation will activate the siren.
NO: A proximity anti approach violation will not activate the siren and
will be regarded as trouble by the system.
Siren Auxiliary = Tamper
No
Yes/No
This parameter relates to the bus siren.
YES: A siren auxiliary trouble will be regarded as tamper alarm by the
system.
NO: A siren auxiliary trouble will be regarded as trouble by the system.
RF Wake‐Up
No
Yes/No
Determines whether the system can wake the 2‐way keypad up during
exit/entry times or when failing to set the system.
YES: The system wakes the keypad.
NO: The system cannot wake up a 2‐way keypad. Use this option to save
battery life.
Keyfob Instant Arm
No
Yes/No
YES: Away arming from any 2‐way remote control will be instant.
NO: Away arming from any 2‐way remote control will be delayed,
following exit delay 1.