RISCO Group LightSYS 2 User Manual
Page 86
Installer Programming
Page 86
Quick Keys
Parameter
Default
Range
20 Minutes Signal
No
Yes/No
YES: Prior to arming the system, the system will check for zones that did
not send a signal for more than 20 minutes. These zones will be regarded
as not ready. A partition assigned with a not ready zone cannot be
armed.
NO: Prior to arming, the system will not check whether a zone did not
send a signal for more than 20 minutes.
Attenuation
No
Yes/No
YES: The LightSYS2 device will be attenuated by six dB during the
communication test.
NO: The LightSYS2 device works in normal operation mode.
System: Controls: PD6662:2010
Quick Keys
Parameter
Default
Range
PD6662:2010
This section refers to controls that apply to DD243 approvals.
Bypass Exit/Entry
Yes
Yes/No
YES: It is possible for the user to bypass an Exit/Entry zone.
NO: An Exit/Entry zone cannot be bypassed.
Entry Disable
No
Yes/No
YES: The alarm confirmation process will be disabled when the entry
time starts.
NO: The alarm confirmation process will start when the entry time
starts.
Route Disable
No
Yes/No
YES: The panel disables the entry route zones (EX/EN, EX (OP)/EN,
followers and Final Exit) from participating in the alarm confirmation
process when the entry time starts.
Note
Sequential confirmation can still be established from two confirmed
zones, located off the entry route.
NO: The entry route zones will participate in the alarm confirmation
process when the entry time starts.