RISCO Group LightSYS 2 User Manual
Page 210

Using the Installer Non‐Programming Menus
Page 210
Siren Test
Activates the alarm sound from each BUS sounder, from the Bell terminals on the main
board and activates utility outputs defined as Bell Trigger
( ).
Strobe Test
Activates all strobes in connected BUS sounders and activates utility output defined as
Follow Strobe
( ).
Zone Resistance
Tests the resistance and voltage level of the wired zones in the system. Use the
key to
toggle between resistance and voltage of each detector
Diagnostics
Activates the relevant tests for:
Main Unit: Tests the standby battery level of the main board and the system
version.
Bus Zones: Performs a diagnostic test to the Bus zones in the system and displays
the relevant information for each detector.
Zone Expander: Performs a diagnostic communication test on installed zone
expanders and tests its version.
Power supply: Performs a diagnostic communication test on installed power
supplied expanders and displays the relevant information for each
power supply.
Siren: Performs a diagnostic communication test on installed bus sirens and
displays the information regarding each siren (depending on the siren
type).
GSM: Performs a diagnostic test for the following parameters of the plug in GSM
module:
Signal (RSSI): Displays the signal level measured by the GSM module.
(0=No signal, 5= Very high signal)
Version: Displays information regarding the GSM module version
IMEI: View the IMEI number of the GSM module. This number is used
for identification of the LightSYS2 at the RISCO IP receiver when using
GSM or GPRS communication.
IP: Performs a diagnostic test for the following parameters of the plug in IP
module:
IP Address: View the IP address of the LightSYS
Version: View the IP module software version