RISCO Group LightSYS 2 User Manual
Page 79

Installer Programming
Page 79
Quick Keys
Parameter
Default
Range
24‐Hour Bypass
No
Yes/No
YES: It is possible for the user to bypass a 24‐hour zone.
NO: It is not possible for the user to bypass a 24‐hour zone.
Technician Tamper
No
Yes/No
YES: It is necessary to enter the installer code to reset a tamper alarm (
). Therefore, resetting a tamper alarm requires the intervention of the
alarm company. However, the system can still be armed although the
tamper indication is on.
NO: Correcting the problem resets a tamper alarm, requiring no alarm
company assistance.
Technician Reset
No
Yes/No
YES: It is necessary to enter the installer code to reset an alarmed
partition after it has been disarmed. This requires the intervention of the
alarm company.
Note
Before the Ready LED/
can light., all zones within the partition must
be secured.
NO: Once an alarmed partition is reset the Ready LED/
lights when all
zones are secured.
Engineer Tamper
No
Yes/No
YES: After a tamper alarm, the system is not ready to arm and the tamper
indication (
) LED is not restored. This requires the intervention of the
alarm company.
NO: After a tamper alarm is restored the system is ready.
Low Battery Arming
Yes
Yes/No
YES: Allows arming of the system when a low battery condition is
detected (also in the Power Supply expansion module).
NO: Arming the system is disabled when a low battery condition is
detected.
Bell 30/10
No
Yes/No
YES: Any internal sounders cease to sound for 10 seconds after each 30
seconds of operation.
NO: Any internal sounders operate without interruption.