Installer Programming
Page 120
Resistance
In the LightSYS2 you have the ability to define separately the end‐of‐line
resistance of the zones on the main unit
Selection is done by the software with the following available options
Specify here the optional circuit resistance configuration.
Custom
2.2K; 2.2K
4.7K; 6.8K
6.8K; 2.2K
10K; 10K
3.74K; 6.98K
2.7K; 2.7K
4.7K; 4.7K
3.3K; 4.7K
1K; 1K
3.3K; 3.3K
5.6K; 5.6K
2.2K; 1.1K
2.2K; 4.7K
N/C: Uses normally‐closed contacts and no terminating End‐of‐Line
Resistor.
DEOL: Uses normally‐closed (NC) contacts in a zone using two 10 KΩ
of End‐of‐Line Resistors to distinguish between alarms and tamper
conditions
ZZ
Input Response Time 500 10/500mSEC
10 mSEC 500mSEC
Set the duration for which a zone violation must exist in order for the
zone to trigger an alarm condition.
ZZ
(F Univ. only)Anti‐Sabotage Disabl Enable/Disable
Enable or disable
the transmitter’s anti‐sabotage magnet.
ZZ
(F SP only)Shutter Pulse 02 01‐16
Define here the number of pulses for the input.