beautypg.com

RISCO Group LightSYS 2 User Manual

Page 120

background image

Installer Programming

Page 120



Resistance 

In the LightSYS2 you have the ability to define separately the end‐of‐line 
resistance of the zones on the main unit  

Selection is done by the software with the following available options 

Specify here the optional circuit resistance configuration.

Custom
2.2K; 2.2K
4.7K; 6.8K
6.8K; 2.2K
10K; 10K


3.74K; 6.98K

2.7K; 2.7K

 4.7K; 4.7K
3.3K; 4.7K
1K; 1K
3.3K; 3.3K
5.6K; 5.6K
2.2K; 1.1K
2.2K; 4.7K

 

N/C: Uses normally‐closed contacts and no terminating End‐of‐Line 
Resistor.  
DEOL: Uses normally‐closed (NC) contacts in a zone using two 10 KΩ 
of End‐of‐Line Resistors to distinguish between alarms and tamper 
conditions 

ZZ

Input Response Time                500                    10/500mSEC

 

 10 mSEC 500mSEC  
Set the duration for which a zone violation must exist in order for the 
zone to trigger an alarm condition. 

ZZ

(F Univ. only)Anti‐Sabotage  Disabl             Enable/Disable

 

 Enable or  disable 

the transmitter’s anti‐sabotage magnet. 

ZZ

(F SP only)Shutter Pulse              02                     01‐16

 

Define here the number of pulses for the input.