RISCO Group LightSYS 2 User Manual
Page 133

Installer Programming
Page 133
Quick Keys
Parameter
Strobe Trigger
A latched output that is used to trigger a strobe. The output is
activated when one of the defined partitions is in alarm mode or
during squawks. The output will be activated until the alarm is
disarmed. The output is also activated in test mode.
Note:
A tamper alarm will not activate the output if all the partitions are
disarmed.
Fail To Arm
Activates when one of the defined partitions fails to arm and
deactivates at user reset.
Confirm Alarm
The output activates when a confirmed alarm occurs in a partition
and deactivates at the restore of the alarm confirmation. RISCO
recommends that you use this output for the Red‐Care STU
Confirmed Alarm channel.
Duress Follow
Activates the Utility Output when a DURESS alarm is initiated at the
keypad related to the selected partition(s).
1.
Press
. The following display appears:
P=1234 UO=XX
Y...
Note:
The XX in the UO=XX refers to the number of the Utility Output currently being
programmed
.
2. Use the
key to toggle between Y Yes and N No to designate the partition(s)
that will activate the selected Utility Output (UO),
‐OR‐
Press the partition number [1 to 4] to select or deselect it
3. Press
and proceed to Pattern of Operation, page 136 , to set the pattern and
duration of operation