RISCO Group LightSYS 2 User Manual
Page 72
Installer Programming
Page 72
Quick Keys
Parameter
Default
Range
TX Supervise
058
1‐255 seconds
Specifies how often a bi‐directional wireless device generates a
supervision request to the system.
If any of the accessories does not respond to the request, at least once,
during the RX Supervision time, the system will regard the accessory as
Lost.
Notes
The device will generate the supervision message according to the
time defined.
Important: The RX Supervision time should be higher than the Tx
Supervision time in order to eliminate false lost event.
Service Mode
020
1‐255 seconds
The time period that all tampers (main unit and accessories) can be opened
for purposes of battery replacement without triggering a tamper alarm.
AC Off Delay
30
001‐255 minutes
In the case of a loss of AC power, this parameter specifies the delay period
before reporting the event or operating the programmable output. If the
delay time is set to zero, there will be no delay period.
Guard Delay
30
01‐99 minutes
Specifies the time period that the system will be unset after an authorized
user enters a Guard code.
Swinger Limit
00
00‐15 times
A swinger is a repeated violation of the same zone, often resulting in a
nuisance alarm and usually due to a malfunction, an environmental
problem, or the incorrect installation of a detector or sensor.
This parameter specifies the number of
violations of the same zone
reported
during a single armed period, before the zone is automatically bypassed.
Notes
Enter 00 to disable the swinger shutdown.
EN 50131 compliance with swinger limit of no more than 10 times