Installer Programming
Page 85
Quick Keys
Parameter
Default
Range
Restore Alarm
No
Yes/No
YES: The user must confirm that he is aware that alarm occurred in the
system before rearming the system. The system/partition will be in “Not
Ready” status until it confirms the alarm. The user needs to confirm the
alarm by going to View > Alarm Memory
NO: The user does not need to confirm the alarm before rearming the
system.
Mandatory Event Log
No
Yes/No
YES: Only mandatory events (specified in the EN standard) will be
displayed in the event log.
NO: All the events will be displayed in the event log.
Restore Troubles
No
Yes/No
YES: The user must manually confirm the restoral of each trouble to a
normal condition. This is done from the User menu > View Trouble >
Press OK.
NO: The restoral report of each trouble is automatic .
Exit Alarm
Yes
Yes/No
YES: A violated zone outside the exit route will generate an alarm during
the exit time. A report to the monitoring station for arming the system is
sent at the beginning of the arming procedure.
NO: A violated zone outside the exit route will cancel the arming
process. A report to the monitoring station is sent at the end of a
successful arming procedure.
Entry Delayed Alarm
No
Yes/No
This feature is used to reduce false alarm reports to the MS.
YES: The report to the MS and the siren alarm will be delayed for 30
seconds or until the end of the predefined entry delay (the shorter time
of the two) following a violation of a zone outside the entry route.
NO: A violated zone outside the entry route will generate an alarm
during the entry time and a report will be sent to the MS.