Page 53
Installing Bus Devices
Page 53
Sounders
For detailed information of installation the bus Sounders (ProSound or Lumin 8) refer to the
manuals supplied with the products
ProSound
Figure 3-14: ProSound Bus Wiring
To install LightSYS‐compatible bus sounders
1. Connect the siren according to Figure 3‐14.
2. Set the related DIP switches for bus mode operation.
a. Set DIP switch DIP 1:SW4 should be in ON position for ProSound bus
connection
b. DIP switch DIP 1:SW5 : Defines the siren sound rhythm (ON = Slow, Off =
Fast)
c.
DIP switch DIP 1:SW1‐3: Set ID Bus Number. Up to 4 sirens can be
connected to the LightSYS2.
d. DIP switch DIP 2:SW2: Set different siren sound
Notes:
The sounder will not operate when a battery is not connected or no power
supply is connected to the PS terminals.
After powering‐up the sounder, it will not operate for a period of 20 seconds
(sound and strobe) in order to avoid accidental activation during installation.
After powering‐up the sounder, the sounder inputs (C+/C‐) will cause activation
only if they have been in normal (silent) state at least for 10 seconds.
The PROX and TRBL outputs are deactivated in bus mode configuration.
To protect the battery against deep discharge, the battery will be automatically
disconnected below 10.5 VDC.