Installing Bus Devices

Page 53

Sounders

For detailed information of installation the bus Sounders (ProSound or Lumin 8) refer to the 
manuals supplied with the products 

ProSound

Figure 3-14: ProSound Bus Wiring

To install LightSYS‐compatible bus sounders 

1. Connect the siren according to Figure 3‐14.  
2. Set the related DIP switches for bus mode operation. 

a. Set DIP switch DIP 1:SW4 should be in ON position for ProSound bus 

connection 

b. DIP switch DIP 1:SW5 : Defines the siren sound rhythm (ON = Slow, Off = 

Fast) 

c.

DIP switch DIP 1:SW1‐3: Set ID Bus Number. Up to 4 sirens can be 
connected to the LightSYS2. 

d. DIP switch DIP 2:SW2: Set different siren sound 

Notes:

 The sounder will not operate when a battery is not connected or no power 

supply is connected to the PS terminals. 

 After powering‐up the sounder, it will not operate for a period of 20 seconds 

(sound and strobe) in order to avoid accidental activation during installation.  

 After powering‐up the sounder, the sounder inputs (C+/C‐) will cause activation 

only if they have been in normal (silent) state at least for 10 seconds.  

 The PROX and TRBL outputs are deactivated in bus mode configuration. 
 To protect the battery against deep discharge, the battery will be automatically 

disconnected below 10.5 VDC.