5. When the LED stops flashing rapidly, the keypad beeps twice and displays the
following:
Data is saved
Please wait…
6. Then the keypad returns to the normal initial display.
7. Remove the PTM from the PLUG 1 connector
8. Position the default DIP switch 2 to the OFF position.
9. The PTM now contains a copy of the main panelʹs configuration
To load the PTM’s stored configuration into a main panel:
1. Position the PTM on the PLUG 1connector on the Main with the red LED facing the
row of terminals on the main panel. The red LED flashes slowly.
2. Position the default DIP switch 2 to the ON position.
Note:
The DIP2 should be software enabled (Installer programming: Quick key 1 5 1)
3. Momentarily remove all power from the main panel (both AC and Standby Battery).
4. Restore all power to the main panel. After a moment, the LED on the Program
Transfer module flashes rapidly, indicating that the information is being copied
from the PTM to the main panel. The LCD keypad displays the following:
Please wait…
5. When the LED stops flashing rapidly, the keypad beeps once, and its display returns
to the normal initial display.
6. Remove the PTM from the bus connector PLUG 1.
7. Position the default DIP switch 2 to the OFF position.
8. From an LCD keypad, access the main Installer Programming menu.
9. Without making any changes, exit the main Installer Programming menu by
pressing [0]. The LED on the Program Transfer Module flashes rapidly, and the
keypad displays the following:
Do you want to
Save the data? Y
10. Press
.
11. The keypad beeps twice and displays the following:
Data is saved
Please wait…
12. Then the keypad returns to the normal initial display, and the main panelʹs
configuration now matches the PTM.
13. Reset its TIME and DATE, which were lost when power was removed.