RISCO Group LightSYS 2 User Manual
Page 197

Installer Programming
Page 197
Quick Keys
Parameter
Default
Range
Controls
Advance through the parameters to be controlled:
Emergency
The keypad’s emergency keys can be enabled or disabled per
keypad.
Yes: Enable the operation of the keypad’s emergency keys.
No: Disable the operation of the emergency keypad’s keys.
Multi view (Bus)
Yes: The keypad will display the status of all masked partitions.
No: The keypad will display only the status of its partition.
Exit beeps (2‐Way with bypass unit;)— Sounds beeps during
exit time in stay arming.
Serial Number
: The identifying 11‐digit number of the keypad
(display only)
Function Key
(2‐Way)
Disable
The keypad’s function keys can be enabled or disabled per
keypad.
Yes: Enable the operation of the keypad’s function keys.
No: Disable the operation of the keypad’s function keys.
Panic
: Sends a panic alarm to the monitoring station
M/S Listen/Talk— The system dials the Monitoring Station to
establish 2‐way communication..
UO Control 1
(2‐Way): Assign outputs that will be activated by a
long press on key
UO Control 2
(2‐Way): Assign outputs that will be activated by a
long press on key
UO Control 3
(2‐Way): Assign outputs that will be activated by a
long press on key
Slim 2‐way Wireless keypad features:
Label: provide a meaningful name (see page 62 for details)
Partition assignment: (in most cases this is left as 1)
Masking : enables user / keypad authorization granularity per
partition
Controls: enables emergency, exit beeps
Serial Number
Function Key > panic , MS Listen‐talk, Disable
UO 1 – 3