RISCO Group LightSYS 2 User Manual
Page 159

Installer Programming
Page 159
Quick Keys
Parameter
Default
Range
Controls
Allows to program controls related to operation with the monitoring
station
Call Save
No
Yes/No
YES: For reducing MS traffic congestion, the system holds all non‐urgent
events (for example, opening/closing reports, test transmissions) for up to
12 hours (programmable) and sends them as a batch at a less busy time,
for example, at night. (Refer to Dialer: Periodic Test, page 160)
NO: All events are transmitted as they occur.
Show Kissoff
No
Yes/No
YES: The keypad indicates when the dialer receives the kissoff signal from
the MS’s receiver.
NO: The keypad does not indicate on receipt of the kissoff signal.
Show Handshake
No
Yes/No
YES: The keypad indicates when the dialer receives the handshake signal
from the MS’s receiver.
NO: No indication for establishing communication with the central
station’s receiver
Audible Kissoff
No
Yes/No
YES: There is an audible sound emitted from the keypad when the dialer
receives the kissoff signal from the MS’s receiver.
NO: There is no audible sound on receipt of the kissoff signal.
SIA Text
No
Yes/No
Yes: SIA format report to MS will support text transmission over the
voice channel. Note ( the MS receiver should support the SIA Text
protocol)
No: SIA format will not support text