RISCO Group LightSYS 2 User Manual

Page 73

background image

Installer Programming

Page 73

Quick Keys

Parameter

Default

Range



Redial Wait  

 30

  

 0–255 seconds

 

The number of seconds between attempts at redialing the same phone 
number. 
Applies to the MS Retries parameter, described on page 160 and FM 
Retries
 described on page 173.  



Last Exit Sound  

 10 

 

 01–255 seconds

 

Defines the final seconds of the Exit Time for which the beep sound will 
change (keypads), indicating that Exit Time period is about to expire. 



Buzzer at Stay  

 15

 

01‐99 seconds

 

Defines how much time keypads buzzer will sound before the external 
sounders start to operate while an alarm occurs in STAY mode. The timer 
is relevant only if the system control Bell>Buzzer is defined ed as Yes.  



Status Timer  

 000

  

 0‐255 seconds

 

Defines if the status of the system will be displayed while the system is 
armed . When the time is defined as 0, the system status will be displayed 
during the Arm period. When the time is not 0, the system status will be 
displayed only during this interval after the Arm period starts. 



Service Timer  

 000

  

 0‐255 weeks

 

Use this timer to periodically generate a “Service required” message so 
that the user is reminded that a service call is required. The user may 
continue to arm and disarm the system. When this time is other than 0, 
the panel will count down the time. When the time expires, a service 
message will be displayed on all LCD keypads whenever the keypad is on 
Disarm display. 
To clear the message, the installer needs to reset the time, enter a code 
from the Anti Code menu or perform a “remote reset” to the panel. 



Payment Timer  

 000

  

0‐255 weeks 

 

Use this timer as a reminder for the user payment due. When this time is 
other than 0, the panel will count down the time. One week before the 
time expires a service message will be displayed as a pre‐warning on all 
LCD keypads whenever the keypad is on Disarm display. At due time, 
the system is prevented from being armed. 
To reset the time, enter a code from the Anti Code menu or Installer code, 
or perform a “remote reset” to the panel.