RISCO Group LightSYS 2 User Manual
Page 162
Installer Programming
Page 162
Quick Keys
Parameter
Default
Range
Confirmation
The confirmation times relate to the Zone Sequential Confirmation
(Alarm Confirmation, see
)
Confirm Start (Confirm
delay time)
000
1–120 minutes
Specifies that the system cannot start a sequential confirmation process
until the timer has expired. This time starts when the system has set and
will prevent confirmed alarms being generated in situations when a
person has been accidentally locked in the building.
Confirm Time Window
030
30–60 minutes
Specifies a time period that starts when an alarm is triggered for the first
time. If a second alarm is triggered before the end of the confirmation
time window, the system will send a confirmed alarm to the monitoring
station
Report Split
The Report Split menu contains parameters that enable the routing of
specified events to up to three MS receivers.
MS Arm/Disarm
1
st
backup 2
nd
Reports Arming/Disarming (meaning Closings/Openings) events to the
MS
Do not call (no report).
Send 1
st
: Reports Openings and Closings to MS 1.
Send 2
nd
: Reports Openings and Closings to MS 2.
Send 3
rd
: Reports Openings and Closings to MS 3.
Send all: Reports Openings and Closings to the all defined MS.
1
st
Backup 2
nd
: Reports Openings and Closings to MS 1. If
communication is not established, calls MS 2.
1
st
Backup 2
nd
3rd: Reports to MS 1. If communication is not
established calls MS 2. If communication is not established again calls the
MS.