Quick Keys
Parameter
Default
Range
Type
Defines the way the external lamp will be operated.
ALWAYS ON–The lamp is always on.
ALWAYS OFF–The lamp is always off.
SCHEDULER– The lamp operates according to the time defined
under the Sounder Lamp menu (Quick Key:
).
Brightness
05
(01–10%)
Used to set the brightness level of the external lamp.
Power Source
SAB
SAB/SCB
(Only for Lumin 8)
Used to define the SAB or SCB power source mode of the LuMIN8.:
SAB—Power supply for the sounder will be drawn from the control
panel.
SCB—Power supply for the sounder will be drawn from the
sounder’s rechargeable battery.
Siren Current
Standard
Standard/Low
(Only for Lumin 8)
Set the sounder current mode.
LOW – The sounder output will be reduced to 106dB 150mA.
STANDARD ‐ The sounder output will be 112dB 350mA (assuming
single piezo head).
Alarm Sound
(Only for Lumin 8)
Set the type of the alarm sound. Specify which of four alarm sounds is
associated with this siren.