RISCO Group LightSYS 2 User Manual
Page 102

Installer Programming
Page 102
Quick Keys
Parameter
Default
Range
ZZ
Latch Keyswitch
Connect an external SPST latched (non‐momentary) keyswitch to any
zone terminals given this designation and operate the keyswitch, as
follows:
After arming one or more partitions using the keyswitch and then
disarming using the keypad, the related partitions will be disarmed.
In order to arm the partition using the keyswitch again, turn the key
to the disarm position and then to the arm position.
If a keyswitch latch is assigned to more than one partition and one of
the partitions is armed by using the keypad (the keyswitch stays in
the disarm position), then:
When changing the position of the keyswitch to the arm
position, all the disarmed partitions, which belong to this
keyswitch, will be armed.
When turning the keyswitch to the disarm position, all the
partitions will be disarmed.
ZZ
Entry Follower + Stay
All
Assigned to motion detectors and to interior doors protecting the area
between the entry door and the keypad, as follows:
In STAY (ARM) mode, a zone(s) given this designation behaves like
an Exit/Entry zone and is subject to the Entry and Exit Delay time
periods specified under Exit/Entry Delay 1. (Refer to Exit/Entry
Delay 1, page 95.)
In AWAY (ARM) mode, a zone(s) given this designation behaves
like an Entry Follower Zone and causes an immediate intrusion
alarm when violated unless an Exit/Entry zone was violated first.
If so, an Entry Follower + Stay zone(s) remains bypassed until the
end of the Entry Delay period.
ZZ
Pulsed Keyswitch Delay
Used to apply the Exit/Entry Delay 1 parameter to the momentary
keyswitch operation. (see
ZZ
above)
ZZ
Latch Keyswitch Delay
Used to apply the Exit/Entry Delay 1 parameter to the latched keyswitch
operation. (see
ZZ
above.)