RISCO Group LightSYS 2 User Manual
Page 146

Installer Programming
Page 146
Quick Keys
Parameter
Default
Range
MS report
Urgent
events
MS 1 Polling
State
MS 2Polling
State
MS 3 Polling
State
Do not call
N/A
N/A
N/A
Call 1
st
Primary
N/A
N/A
Call 2
nd
N/A
Primary
N/A
Call 3
rd
N/A
N/A
Primary
Call All
Primary
Primary
Primary
1
st
Backup 2
nd
Primary
If (MS 1 is OK)
Secondary
else (MS#1 Fails)
Backup
N/A
1
st
Backup
2
nd
3rd
Primary
If (MS#1 is OK)
Secondary
else (MS#1 Fails)
Backup
If (MS#2 is OK)
Secondary
else (MS#2
Fails)
Backup
1
st
Backup 3
rd
Call 2
nd
Primary
Primary
If (MS#1 is OK)
Secondary
else (MS#1
Fails)
Backup
2
nd
Backup 3
rd
Call 1
st
Primary
Primary
If (MS#2 is OK)
Secondary
else (MS#2
Fails)
Backup
MS Polling example:
When selecting MS 1 (GPRS), MS 2 (GPRS) and split report option 1
st
Backup 2
nd
(using the default primary, secondary and backup time
intervals), the report process will be as follows:
In a normal state:
Polling through the GPRS network using the GSM module will occur
every 90 seconds according to the primary time interval to MS 1 and
every 3600 seconds (1 hour) according to the secondary time interval to
MS 2.