Installer Programming
Page 66
3. Enter the bus detector ID number as set by the detectorʹs DIP switches (01‐32)
Note:
The display ʺ(x:yy) Type: Noneʺ represent the bus detector location in the
system. In the 0:yy designation, the 0 denotes that the bus detector is on the
main unit and is not assigned to a bus zone expander. The yy represents the bus
detector ID number (up to 32) as set by the detectorʹs DIP switches.
4. Using the arrow keys move to the Type field. Use the
key to select the
detectorʹs type.
5. Repeat steps 2 ‐ 4 for other bus detectors.
Step 2: Set Bus Zone Basic Attributes
1. From the main Installer menu select [1] Zones > [1] Parameters > [1] One by
One
.
2. Select the zone number that the bus zone was assigned to and press
.
3. Configure the parameters for the relevant bus detector.
Step 3: Programming the Bus Detectors Advanced Parameters
1. From the main Installer menu select [2] Zones > [1] Parameters > [2] By
Category > [7] Advanced > [4] BZ Parameters
.
2. Select the zone number that the bus zone was assigned to and press
.
3. Configure the parameters for the relevant bus detector.
Programming bus detectors on a bus expander
Using bus expanders you can create a separate bus loop that is used only for the bus
detectors connected to it. The separate bus loop increases the total system security in
case a certain bus detector is sabotaged. Up to four bus expanders can be added to
the LightSYS (See diagram page 55)
Step 1: Adding the Bus Expander to LightSYS2
Note:
If you already performed Auto Settings skip to Step 2 below: Assign Bus Detectors to
a Zone ID and set basic parameters.
1. From the main installer menu press
to enter the Bus Expander
menu.
2. Using the arrow and numeric keys select a bus zone expander ID.
3. Using the arrow keys move to TYPE. Use the
key to select a BZE32 and
press
.