RISCO Group LightSYS 2 User Manual
Page 215
Technical Specifications
Page 215
* For full technical information refer to the manual of the siren
* Lumin8 ( RS200WA, RS200WAP)
Input DC Power
Regulated 13.0‐ 14.2V
Current Consumption
Single piezo: 350mA (Regulated)
Twin piezo: 450mA (Regulated
)
Battery charging current
15 mA maximum
Speaker Sound level
Single piezo: 111dbA Twin piezo: 114dbA)
Main Panel Connection
4‐wire BUS, up to 300 m (1000 ft) from Main Panel
* For full technical information refer to the manual of the siren
Singe Zone Expander (RP128EZ01)
Voltage
13.8VDC +/‐10%
Current
20mA
Main Panel Connection
4‐wire BUS, up to 300 m (1000 ft) from Main Panel
Plug In GSM (RP432GSM)
Voltage
13.8VDC +/‐10%
Current
During Communication ‐ 300mA
During Standby ‐ 30mA
Dimensions
80 mm x 50 mm x 25 mm
Plug In IP (RW132IP)
Voltage
13.8VDC +/‐10%;
Current
90mA maximum
Dimensions
70 mm x 60 mm
Plug In Modem 2400 (RP432MD24)
Voltage
13.8VDC +/‐10%;
Current
20 mA, typical / 60 mA, maximum
Dimensions
70 mm x 25 mm
BUS Expander (RP432EZB)
Voltage
13.8VDC +/‐10%;
Current
20 mA, typical
Main Panel Connection
4‐wire BUS, up to 300 m (1000 ft) from Main Panel
Dimensions
10.5 cm x 6.6 cm x 1.8 cm
KP LRT (Long Range Transmitter)
Voltage
13.8VDC +/‐10%;
Current
10 mA, standby / 1A maximum
Dimensions
227 mm x 173 mm x 124 mm