When communication to MS 1 fails, polling occurs every 90 seconds
according to the backup interval to MS 2. When communication returns
to MS 1, polling reverts back to the secondary time interval and occurs
every 3600 seconds (1 hour) to MS#2.
GPRS
Allows programming parameters that relate for the communication
over the GPRS network.
APN Code
To establish a connection to the GPRS network an APN (Access Point
Name) code is required. The APN code differs from country to country
and from one provider to another (the APN code is provided by your
cellular provider).
The LightSYS2 supports an APN code field of up to 30 alphanumeric
characters and symbols (!, &, ? etc).
APN User Name
Enter user name for the GPRS network (if required). The user name is
provided by your provider.
The LightSYS2 supports a user name field of up to 20 alphanumeric
characters and symbols (!, &, ? etc).
APN Password
The password to the GPRS network as provided by your provider (if
required).
The LightSYS2 supports a user name field of up to 20 alphanumeric
characters and symbols.
The following programming parameters are used to enable sending
Follow Me event messages by e‐mail through GPRS.
Notes:
To enable e‐mail messaging, the GPRS parameters have to be defined .
Mail Host
000.000.000.000
The IP address or the host name of the SMTP mail server.