RISCO Group LightSYS 2 User Manual
Page 136

Installer Programming
Page 136
Utility Output: Pattern of Operation
Quick Keys
Parameter
Default
Range
Pulse N/C
05 seconds
01‐90 seconds
The utility output is always activated (N/C) before it is triggered
(pulled down to negative).
When triggered, it deactivates for the pulse duration specified below
and then reactivates automatically.
1. Press
and then press
.
2. Choose the desired pulse duration, between 01‐90 seconds.
3.
Press
and set the activation by choosing ALL or ANY using
the
key.
4.
Press
and define a label for the UO (refer to the note below).
Latch N/C
The utility output is always Activated (N/C) before it is triggered
(pulled down to negative). When triggered, it deactivates and remains
deactivated (latched) until the operation is restored.
1. Press and then press
.
2. Using the
key select ALL or ANY to set the activation and
press
.
3. Using the
key select ALL or ANY to set the deactivation
and press
.
4. Define the output label and press
Pulse N/O
05 seconds
01‐90 seconds
The utility output is always deactivated (N/O) before it is triggered
(pulled up). When triggered, it activates (is pulled down) for the
pulse duration specified below, then deactivates automatically.
1. Press and then press
.
2. Choose the desired pulse duration, between 01‐90 seconds
3. Press
and set the activation by choosing ALL or ANY using
the
key
4. Select a label for the UO (refer to the note below).