beautypg.com

RISCO Group WL Carbon Monoxide User Manual

Wireless carbon monoxide detector

background image

Page 1

Wireless Carbon Monoxide Detector

Introduction

RISCO Group's Wireless Carbon Monoxide Detector (CO) is an effective
device for detecting the buildup of Carbon Monoxide. Upon detecting the
CO gas, the unit emits an alarm and notifies the control panel.

The main features of your CO gas detector include the following:

Integrated transmitter designed for use with RISCO Group's wireless
alarm systems

Easy to install

Monitoring of carbon monoxide in a continuous manner.

Loud alarm (85 dB) when detecting a buildup of carbon monoxide

Test button

Continuous Self-testing function

What You Should Know About Carbon Monoxide

Carbon monoxide, also known as "CO" by the chemical form, is considered
to be a highly dangerous poisonous gas, because it is colorless, odorless,
tasteless and very toxic. In general, biochemistry phenomena have shown
that the presence of CO gas inhibits the blood's capacity to transport oxygen
throughout the body, which can eventually lead to brain damage.
In any closed space (home, office, recreational vehicle or boat) even a small
accumulation of CO gas can be quite dangerous.
Although many products of combustion can cause discomfort and adverse
health effects, it is CO gas which presents the greatest threat to life.
Carbon monoxide is produced by the incomplete combustion of fuels such
as natural gas, propane, heating oil, kerosene, coal, charcoal, gasoline, or
wood. The incomplete combustion of fuel can occur in any device which
depends on burning for energy or heat such as furnaces, boilers, room
heaters, hot water heaters, stoves, grills, and in any gasoline powered
vehicle or engine (e.g. generator set, lawnmower). Tobacco smoke also
adds CO to the air you breathe.
When properly installed and maintained, your natural gas furnace and hot
water heater do not pollute your air space with CO. Natural gas is known as
a "clean burning" fuel because under correct operating conditions, the
combustion products are water vapor and carbon dioxide (CO2), which is not

toxic. The products of combustion are exhausted from furnaces and water
heaters to the outside by means of a fuel duct or chimney.
Correct operation of any burning equipment requires two key conditions:

(a) An adequate supply of air for complete combustion.
(b) Proper venting of the products of combustion from the furnace through

the chimney, vent or duct to the outside.

Typical carbon monoxide gas problems are summarized here:
(a) Equipment problems, due to defects, poor maintenance, damaged and

cracked heat exchangers

(b) Collapsed or blocked chimneys or flues, dislodged, disconnected or

damaged vents

(c) Downdraft in chimneys or flues. This can be caused by very long or

circuitous flue runs, improper location of flue exhaust or wind
conditions

(d) Improper installation or operation of equipment, chimney or vents
(e) Air tightness of house envelop/inadequate combustion of air
(f) Inadequate exhaust of space heaters or appliances
(g) Exhaust ventilation/fireplace competing for air supply
Potential sources of carbon monoxide in your home or office include
clogged chimney, wood stove, wood or gas fireplace, automobile and
garage, gas water heater, gas appliance, gas or kerosene heater, gas or
oil furnace and cigarette smoke.

Installing the Detector

Selecting the installation location

Since CO gas moves freely in the air, the suggested location is in or as near
as possible to sleeping areas of the home, 30 cm (12 inch) below the ceiling .
For maximum protection, a CO detector should be located outside the
primary sleeping areas or on each level of your home (see Fig 1 for
suggested locations).

Fig. 1

IMPORTANT:

This device is not suitable for installation in a hazardous location, as
defined by the US National Electrical Code.

Do not place the detector in the following areas:
(a) Where the temperature may drop below 4

°C (39°F) or exceed 38°C

(100

°F).

(b) Near paint thinner fumes
(c) Within 1.5 meter (5 feet) of open flame appliances such as furnaces,

stoves and fireplaces

(d) In exhaust streams from gas engines, vents, flues or chimneys
(e) Do not place in proximity to an automobile exhaust pipe; this will

damage the detector

To install the detector:

1. Remove the mounting bracket from your unit according to Fig. 2.

1

2

3

Fig. 2

2. Hold the Mounting bracket against the wall as a template and mark the

locations for the 2 mounting holes.

3. Using a 5 mm (3/16-inch) drill bit, drill two holes at the marks and insert

wall plugs (Fig 3).

Fig. 3

4. Secure the mounting bracket to the wall.
5. Open the battery cover by pushing down on the battery snaps (Fig. 4).

+

-

Fig. 4

6. Insert the batteries (supplied) into the battery compartment. Pay

attention to the correct battery polarity (+) (-) and close the battery
compartment

7. Line up the side slot of the bracket and the detector. Push the detector onto

the mounting bracket until a click is heard (see arrow direction, Fig 3).

8. Pull the detector outwards to make sure that it is securely attached to

the mounting bracket.

Transmitter/Receiver Communication Setup

1.

Set the receiver to Learn mode.

2.

A Write message is sent 10 seconds after the insertion of batteries
into compartment

- and in addition -

When the Tamper is pressed for 3 seconds (the button is pressed

when the detector is placed on the mounting bracket).

3.

Verify that the detector has been identified by the receiver.

LED & BUZZER Indication

The LED light and the buzzer turn on and/or off to indicate various
situations. There are four different light and buzzer operations:

LED

LED Status

Buzzer

Meaning

Green
(Power)

Flashing On and Off
every 30 seconds

Normal

condition

RED
(Alarm)

Flashing Sequential

Alarm

Sound

Alarm

Orange
(service)

Flashing On and Off Sequential Alarm

Sound

Internal self test fail
- service required

All LED's

Flashing

3 beeps for a
period of 3 seconds

Test mode