RISCO Group LightSYS 2 User Manual
Page 132

Installer Programming
Page 132
Quick Keys
Parameter
Bell Stay Off
This parameter causes the output to function as follows:
In Away arming mode, the output will follow the bell activation
in the defined partitions.
In Stay mode, the output will not be activated.
Notes:
If an alarm occurs in a zone that shares more than one partition and
one of the partitions is in Arm mode (while the other is in Stay
mode), the output will be activated, as described above.
In Stay mode, a 24‐hour zone will not activate this output.
Zone Bypass
Activates the output when the relevant partitions are in Away or Stay
mode and any zone in the relevant partitions is bypassed.
Automatic Arm Alarm
Activates the utility output when there is a not ready zone at the end
of the pre warning time during an auto‐arm process. The output
restore shall be on Bell‐ Timeout or at user Disarm.
Zone Loss Alarm
Activates the utility output when there is a lost wireless zone in the
system. The output restore shall be on Bell‐Timeout or at user Disarm.
Bell Trigger
Mainly used for the connection of different external sounders to
different partitions in the UK. Activates the output when one of the
defined partitions is in alarm mode and the bell is triggered. It will be
activated for the programmed bell time out or until alarm is disarmed.
This output generates squawk sounds and has a special sound for fire
alarms.
Note:
In fire alarm the output will not follow the bell delay time (see page
70) but will trigger immediately. It will be triggered in pulsed
sequence: five seconds on and two seconds off.