RISCO Group LightSYS 2 User Manual
Page 119

Installer Programming
Page 119
2-Way Magnet (X73)
Quick Keys
Parameter
Default
Range
ZZ
Serial No.
Normal
The identifying 11‐digit number on the detector sticker
ZZ
Control
ZZ
Supervision No Yes/No
Determines if this zone will be supervised by the system expander
according to the time defined under the timer RX Supervision (see page
71)...
ZZ
LED Enable Yes Yes/No
Defines whether or not the LEDS operation mode is enabled
ZZ
(M&F Univ only)
Magnet Enable Yes Yes/No
Yes (Enable) or No (disable) the transmitter’s magnet.
ZZ
Alarm Hold On On On/Off
Use this parameter to define the minimum period between alarm
broadcasts.
ON: Only one alarm message is transmitted in any 2.5 minute time‐
period
OFF: Alarm detection is immediately transmitted
ZZ
Input Termination: N/O N/O, N/C, DEOL
Use this parameter to program the connection type used for each of the
system’s zones.
(F Shutter only)
Shutter: Specifies that the Input 2 will count the
number of open and close pulses received. If the zone exceeds the
predefined number of pulses, the zone will be tripped and act according
to its type definition. After a 25‐second timeout, the pulse counter is
restarted. The pulse length is the currently defined Loop Response time
period.
N/O: Uses normally‐open contacts and no terminating End‐of‐Line
Resistor.