RISCO Group LightSYS 2 User Manual
Page 118

Installer Programming
Page 118
2-Way PIR, Shock, Flood, Gas, Curtain, High Temperature, Zone Button,
WatchOUT and Wired IR Beam
Quick Keys
Parameter
Default
Range
ZZ
Serial No.
The identifying 11‐digit number on the detector sticker
ZZ
Control
ZZ
Supervision No Yes/No
Determines if this zone will be supervised by the system expander
according to the time defined under the timer RX Supervision (see page
71)..
ZZ
LED Enable Yes Yes/No
Defines whether or not the LEDS operation mode is enabled
ZZ
Anti Mask (WatchOUT Only) No Yes/No
Defines the operation of Anti Masking detection and behaves according
to the settings defined in quick keys
ZZ
ZZ
Detection Mode 2.5 Min 2.5 min/ 2.5 sec
Normal 2.5 Min Fast 2.5 Sec
If automatic detection mode is enabled, designate here the polling
periodicity of alarm generating events.
ZZ
Sensitivity
Defines the visual sensitivity of the detector.
LOW HIGH
LOW MEDIUM HIGH MAXIMUM (WatchOUT only)
(For IR Beam) Defines the sensitivity of the detector (how long must
the beam transmission be interrupted to generate an alarm event)
LOW 900 mSEC MEDIUM 675 mSEC HIGH 450 mSEC
MAXIMUM 225 mSEC