Installer Programming
Page 71
Quick Keys
Parameter
Default
Range
Switch Aux Break
10 seconds
00‐90 seconds
The time that the power supplied to the systemʹs smoke detectors through
the programmable output is interrupted during a user‐initiated smoke
detector reset, typically performed after a fire alarm or automatically
when a fire verification is defined in the system control. (Refer to Double
Verification of Fire Alarms, page 7777, for additional details.)
Note
This feature is supported through any programmable output that is
defined as Switch AUX .
Wireless
Specifies the time intervals relating to the operation of the wireless
module
Jamming Time
None
None, 10, 20 or
30 seconds
Specifies the period of time that the LightSYSʹs wireless module tolerates
unwanted radio frequencies capable of blocking (jamming) signals
produced by the systemʹs transmitters. Once the specified time is reached,
the main panel sends a report code to the alarm receiving center. (Refer to
Jamming Fault, page 224.)
NONE
10 SEC
20 SEC
30 SEC
NONE: No jamming will be detected or reported.
Note:
Different sounds will be produced when jamming is detected, depending
on the defined Audible Jamming time
RX Supervise
0
0‐7 Hours
Specifies how often the system expects to get a signal from the systemʹs
transmitters. If a signal from a zone is not received during the specified
time the zone will be regarded as lost, the system will send a report code
to the monitoring station, and the system status will be ʺNot Readyʺ.
Note:
0
hours disables supervision.
It is recommended to set the supervision time to a minimum of 3 hours