K2 Storage System Instruction Manual

September 7, 2007

Chapter 18 Administering and maintaining the K2 Storage System

2. In the Open File dialog box, browse to the latest controller microcode file for your

controller, select the file, and click

OK

.

3. The Progress Report window appears showing the microcode upgrade task and the

percentage completion.

4. On 100% completion, power cycle the RAID controller chassis, then restart the K2

Media Server.

Downloading disk drive firmware

You might be instructed in K2 release notes to upgrade disk drive firmware. This
allows you to take advantage of the disk drive enhancements and benefit from
improved performance and reliability.

To determine your disk drive type and current firmware version, select a disk drive
icon in the Storage Utility tree view, then note the drive properties reported in the
right-hand pane. Use the following procedure if you need to download disk drive
firmware.

NOTE: The disk drives on each controller are upgraded one at a time which can
take as long as 2 minutes per drive. Take this into consideration when scheduling
the upgrade.

Requirements for this procedure are as follows:

• All K2 Media Clients and other clients must be powered down, or in some other

way disconnected from the K2 Storage System.

• The K2 Media Server through which Storage Utility is connected to the RAID

Storage must be powered up.