Chapter 13 Installing the Nearline 10 Storage System

b. Leave Full Bind unchecked. Refer to

“About full/background bind” on

page 748

.

c. In the

Bind Type

drop down box, select

RAID 6

.

d. In the Available Disks box, select twelve contiguous disks at the top of the list.

(TIP: Use ‘shift-click’ or ‘control-click’ to select disks.).

e. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive light to flash.

f. Click

OK

to close the Bind dialog box and begin the binding process. The

Progress Report dialog box opens, showing the status of the binding process.