Setting up the nh1 k2 media server, Chapter 12 installing the level 30r storage system – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual
Page 556

556
K2 Storage System Instruction Manual
September 7, 2007
Chapter 12 Installing the Level 30R Storage System
(Grass Valley part number 174-8137-00). Refer to the K2 Media Client System
Guide for pinout details.
• Assign a control network IP address to GigE port 1. Use standard Windows
procedures. Refer to
“Networking tips” on page 106
.
• Change the hostname. Use standard Windows procedures.
• Configure SNMP properties so the trap destination points to the NetCentral server
PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.
“K2 Media Server descriptions” on page 653
.
Setting up the NH1 K2 Media Server
If your system has one or more NH1 K2 Media Servers, prepare the servers using this
section.
The Dell PowerEdge 1950 is qualified as the platform for the NH1 K2 Media Server.
Do the following to prepare a NH1 K2 Media Server:
• Install the server in its permanent location. Refer to the rack mount instructions that
you received with the server’s product bundle.
• Provide power to the server.
• Connect cables as follows:
Connect the motherboard GigE port 1 (control) and GigE port 2 (FTP) to control
ports on the GigE switch. If you have more than one NH1 server, balance servers
between the A GigE switch and the B GigE switch.
Connect the Fibre Channel port to the RAID storage device. If you have more
than one NH1 server, balance servers between controller 0 and controller 1.
• Assign a control network IP address to GigE port 1. Use standard Windows
procedures. Refer to
“Networking tips” on page 106
.
• Change the hostname. Use standard Windows procedures.
• Configure SNMP properties so the trap destination points to the NetCentral server
PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.
“K2 Media Server descriptions” on page 653
.
1
2
G
b
2
G
b
1
Fi
b
re Ch
a
nnel
to RAID controller
To control port
on GigE
s
witch
FTP: To control port
on GigE
s
witch