September 7, 2007

K2 Storage System Instruction Manual

543

Preparing Level 30R devices

The L30R RAID chassis has redundant RAID controllers to support the Fibre Channel
connections from the K2 Media Servers. The L30R RAID chassis is also connected
to the GigE control network, which is required for SNMP (NetCentral) monitoring.

On the L30R RAID chassis there are two RAID 1 RANKs (also know as LUNs) for
media file system metadata files and journal files. The remainder of the RAID storage
is RAID 5 or RAID 6 for media.

Optional NH K2 Media Servers are available to provide additional FTP bandwidth.
These servers are available with either a one Gigabit connection or a ten Gigabit
connection. If you have multiple NH K2 Media Servers on a K2 Storage System, they
must all be of the same connection speed. They must be all one Gigabit servers or all
ten Gigabit servers.

The K2 configuration control point PC is connected to the GigE control network. The
K2 System Configuration application runs on this PC for configuring the storage
system.

FTP/streaming traffic accesses the K2 Storage System via the FTP GigE port on K2
Media Servers. FTP/streaming traffic does not go to K2 Media Clients.

Refer to

Chapter 14,

Description of K2 Storage Devices for more information. Also

refer to

“Design considerations for Ethernet switches” on page 759

.

Preparing Level 30R devices

Use the topics in this section to prepare each device so that it is ready to become part
of the Level 30R storage system.

“Setting up the Control Point PC” on page 543

“Setting up the Level 30R redundant GigE switches” on page 544

“Setting up the LS K2 Media Servers for Level 30R” on page 555

“Setting up the NH1 K2 Media Server” on page 556

“Setting up the NH1-10GE K2 Media Server” on page 557

“Setting up the L30R RAID chassis” on page 558

“Preparing K2 Storage System clients” on page 559

Setting up the Control Point PC

To set up the K2 configuration Control Point PC, you have the following options:

• Use the Grass Valley Control Point PC that comes from the factory with software

pre-installed. This includes the K2 System Configuration application, remote
AppCenter, and NetCentral software. Refer to the K2 Media Client System Guide
for rack mount instructions.

• Use a PC that you own and install the required software.

For either option, you must do the following for the Control Point PC that runs the K2
System Configuration application:

• Assign a control network IP address to the PC. Refer to

“Networking tips”.