K2 Storage System Instruction Manual

September 7, 2007

Chapter 12 Installing the Level 30R Storage System

type the following, then press

Enter

:

snmp-server host public 192.168.40.11

23.Enable Authentication traps. Type the following, then press

Enter

:

snmp-server enable traps authentication

This allows NetCentral to test the switch to verify that it can send its SNMP trap
messages to NetCentral.

24.Type the following, then press

Enter

:

menu

When prompted, save the configuration by pressing the y key. The main menu
opens.

25.If you need a trunk for ISLs to gang switches together, use the following steps.

These steps illustrate trunking the last three 1 Gig ports for three 1 Gig ISLs, which
is the recommended configuration for ISLs on all multi-switch K2 Storage
Systems. Refer to

“Design considerations for Ethernet switches” on page 759

and

consult with your Grass Valley representative if your requirements deviate from
the recommended policy:

a. At the main menu, select

Switch Configuration

and press

Enter

.

b. Choose selection

Port/Trunk Settings

and press

Enter

.

c. Press the right-arrow key to choose

Edit

, then press

Enter

.

d. Down arrow until at the bottom of the list of ports and select the last (highest

port number) 1 Gig port in the list.

e. Right-arrow over to the Group column.

f. Use the Space bar and set the bottom 1 Gig port to

Trk1

.

g. Set the next port up also to

Trk1

.

h. Set the next port up also to

Trk1

.

i. Press

Enter

, then right-arrow to

Save

. Press

Enter

and revert to previous menu.

26.Select

Return to Main Menu

and press

Enter

.

27.From the main menu, tab to

Command Line (CLI)

and press

Enter

. The command

prompt appears.

28.Check the version of firmware currently installed on the switch. Type the

following, then press

Enter

:

show flash

Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash

Image Size(Bytes) Date Version

----- ---------- -------- -------

Primary Image : 3287779 03/15/05 M.08.66

Secondary Image : 3287779 03/15/05 M.08.66