Level 2R system power-on procedure
Level 2R power-on procedure page 2
Power on the primary
media file system/
database K2 Media
Server. This is the
server that was
primary when you last
powered down the K2
Storage System.
From the control
point PC, in the K2
System
Configuration
application, open
Server Control
Panel
.
Begin record/play
operations.
Level 2R K2 Storage
System power-on complete
Put the K2 Media Server into service:
In Server Control Panel, click
Start
to
start Failover Monitor.
No
In Server Control Panel,
check the Failover Monitor
indicator.
Yes
No
Yes
Green
indicator?
Elapsed time:
3 minutes
Power on K2
Media Clients.
Power on backup media file
system/database K2 Media Server
In Server Control Panel, check
the media file system indicator.
Check all
Server
Control
Panel
indicators
No
Yes
In Server
Control Panel,
check the
media file
system
indicator.
Yes
No
Green
indicator?
Elapsed time:
30 seconds
Green
indicator?
Elapsed time:
3 minutes
Green
indicators?
Elapsed time:
3 minutes
From the control point PC, at the command
prompt, ping the K2 Media Server.
No
Yes
K2
Media Server
responds to ping?
Elapsed time:
3 minutes
Begin record/play
operations.
Power on generic
iSCSI clients.
In Server Control
Panel, click
Start