beautypg.com

Setting up the l10r raid chassis – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual

Page 346

background image

346

K2 Storage System Instruction Manual

September 7, 2007

Chapter 8 Installing the Level 10R Storage System

• Change the hostname. Use standard Windows procedures.

• Configure SNMP properties so the trap destination points to the NetCentral server

PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.

Also refer to

“K2 Media Server descriptions” on page 653

.

Setting up the L10R RAID chassis

Do the following to prepare the L10R RAID storage devices:

• Install the chassis in its permanent location. After mounting the chassis in the rack,

you must secure brackets to the front rail to support the Grass Valley bezel. Refer
to the K2 Lx0 RAID Instruction Manual for rack mount instructions.

“Connect the L10R RAID Primary and Expansion chassis” on page 346

“Power on the L10R RAID chassis” on page 347

In addition, you will configure network settings, SNMP settings, and bind RAID
disks. These tasks are part of the K2 System Configuration application and Storage
Utility procedures later in this chapter.

On the L10R RAID, you do not need to manually set a Fibre Channel address ID on
controllers or a chassis address on Expansion chassis.

Also refer to

“K2 RAID storage description” on page 659

.

Connect the L10R RAID Primary and Expansion chassis

Connect Ethernet, Fibre Channel, and SAS cabling as shown.