Chapter 6 Installing the Nearline Storage System
Power on the L3 RAID chassis
Your preparations for L3 RAID storage are now complete.
K2 configuration and NetCentral
Before you begin using the K2 System Configuration application to configure the
storage system, you should set up the NetCentral system according to the following
requirements:
•
NetCentral installed
— NetCentral server software must be installed on a
NetCentral server PC. This can be the K2 configuration Control Point PC or
another PC that has network communication with the K2 Storage System control
network.
•
Device providers installed
— A device provider must be installed on the NetCentral
server PC for each type of device in the K2 Storage System. For a nearline storage
system, the following device providers must be installed:
POWER
SERVICE
K2
RAID STORAGE
!
Power Cords
(115V/2
3
0V)
Power-up Verification
DIR
a
nd
S
VP LED
s
on the RAID controller
s
a
re
b
linking green
Di
s
k Link LED i
s
s
te
a
dy ON green.
FLT
a
nd BAT LED
s
a
re OFF.
The front Power LED i
s
ON,
S
ervice LED i
s
OFF
a
fter
ab
o
u
t 5 min
u
te
s
.
Refer to the L3 RAID Instruction M
a
nu
a
l if there i
s
a
pro
b
lem.
Power LED
Disk Link
LED
Disk Link
LED
Connect power cords, and turn on power as shown.
You must power-up any RAID Expansion chassis
prior to, or at the same time as the RAID Controller
chassis. Verify power-up as shown.
Service LED