Setting up the level 2 gige switch – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual
Page 34

34
K2 Storage System Instruction Manual
September 7, 2007
Chapter 2 Installing the Level 2 Storage System
Setting up the Level 2 GigE switch
These procedures are for the HP ProCurve switch.
For iSCSI traffic, you must use the HP ProCurve switch. Both the 3400cl series and
2900 series switches are qualified for iSCSI traffic, and both types are fully
compatible and can coexist on the network.
For control and FTP/streaming traffic, it is allowed to use a different brand of switch,
such as a Cisco Catalyst switch, if required by your site. If you are using a non-HP
switch, apply the information in the following procedures accordingly. Refer to the
documentation you received with the switch as necessary.
“Design considerations for Ethernet switches” on page 759
• Use CAT5e or CAT6 cables. The maximum cable length is 50 meters for CAT5e
and 100 meters for CAT6.
• Assign an IP address and logon to the switch. Refer to
switch via serial connection” on page 35
• Set up VLANs on the switch. Refer to
“Configuring the GigE switch via the Web
.
• Install the switch in its permanent location.
• Provide power to the switch.
• Connect cables as follows:
3400cl series switch
2900 series switch
To the media ports make one iSCSI connection from each K2 Media Client or other
iSCSI client, and two iSCSI connections from the K2 Media Server.
To the control ports make a connection from each K2 Media Client or other iSCSI
client, from the RAID storage chassis, and from the control point PC. Also make
the FTP network connection and the control network connection from the K2
Media Server.
Media Ports
Control Ports
1 - 19 odd
2 - 20 even
Media Ports
Control Ports
1 - 19 odd
2 - 20 even