Chapter 11 Installing the Level 30 Storage System

If the RAID chassis has two controllers, you can press the power button on either
controller. You do not need to press both power buttons.

Pressing the power button on a controller also powers on any connected Expansion
chassis. There are no power buttons on Expansion chassis.

3. Release the power button when the Power Good LED on the power supply is

illuminated. This takes 1-3 seconds.

4. Wait while the primary RAID chassis performs self-test and initialization. This

takes about four minutes. While this is taking place, the RDY LED is illuminated
with a steady on light.

5. Watch for the RDY LED to begin blinking at one second intervals. The LED might

turn off and back on two times before starting the one second blink pattern. When
the RDY LED is blinking at one second intervals, the self-test and initialization is
complete and the chassis is ready for use.

Your preparations for L30 RAID storage are now complete.

Preparing K2 Storage System clients

Any devices that function as iSCSI clients to the K2 Storage System must be prepared
with the following requirements:

• One or more connections to the control network.

• A static IP address for the control network.

• For a non-redundant K2 Storage System, one connection to the media (iSCSI)

network.

Additional steps that are required for Aurora Edits include the following:

• Implement Aurora Edit security features.

• Install SNFS software and K2 software.

For more information, refer to the Aurora Edit Installation and Configuration Guide.

For more information refer to the K2 Media Client System Guide.

K2 configuration and NetCentral

Before you begin using the K2 System Configuration application to configure the
storage system, you should set up the NetCentral system according to the following
requirements:

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

BBU IN

MODEM

FLT/LNK

HPE

FLT

A/L

BACKUP

ACT/LNK

LNK/ACT

FLT

HP

5 4 3 2

RDY

LAN

BAT

MNT

ACS

MC

DP1

DP0

HP

1 0

Power Cords

(115V/2

3

0V)

RDY
LED

RDY
LED

Power Good

LED

Power Good

LED