Configuring the level 2r storage system, Prerequisites for initial configuration – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual
Page 100
100
K2 Storage System Instruction Manual
September 7, 2007
Chapter 3 Installing the Level 2R Storage System
Configuring the Level 2R storage system
Use the topics in this section to do the initial configuration of the Level 2R storage
system.
•
“Prerequisites for initial configuration” on page 100
•
“Defining a new K2 Storage System” on page 101
•
“Configuring the server - Part 1” on page 103
•
“Configuring RAID” on page 105
•
“Creating a new file system” on page 110
•
“Configuring the server - Part 2” on page 112
•
“Configuring the redundant server” on page 115
Prerequisites for initial configuration
Before beginning your initial configuration, make sure the devices of the K2 Storage
System meet the following prerequisites. Refer to sections earlier in this manual for
detailed information. Also refer to
Chapter 14, “Description of K2 Storage Devices”
.
Devices
Prerequisite for Level 2R configuration
Control point PC
Ethernet cable connected
Control Point software installed
Control network IP address assigned
Network communication over the control network with all other K2
devices
Power on
Ethernet switch
Ethernet cables connected
Control network IP address assigned
VLANs set up
Trunks set up
Power on
K2 Media Server
Ethernet cables connected
Fibre Channel cable connected
Redundant servers connected by serial cable
Software installed, as from the factory, including QuickTime 7
Control network IP address assigned
Power on for all servers
L2 RAID chassis
Fibre Channel address ID assigned to RAID controller(s)
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on
L2 RAID Expansion
chassis
(optional)
Chassis address assigned (for Fibre Channel)
Fibre channel cable(s) connected
Power on