Chapter 9 Installing the Level 20 Storage System

• Change the hostname. Use standard Windows procedures.

• Configure SNMP properties so the trap destination points to the NetCentral server

PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.

Also refer to

“K2 Media Server descriptions” on page 653

.

Setting up the L20 RAID chassis

Do the following to prepare the L20 RAID storage devices:

• Install the chassis in its permanent location. After mounting the chassis in the rack,

you must secure brackets to the front rail to support the Grass Valley bezel. Refer
to the K2 Lx0 RAID Instruction Manual for rack mount instructions.

“Connect the L20 RAID Primary and Expansion chassis” on page 402

“Power on the L20 RAID chassis” on page 403

In addition, you will configure network settings, SNMP settings, and bind RAID
disks. These tasks are part of the K2 System Configuration application and Storage
Utility procedures later in this chapter.

On the L20 RAID, you do not need to manually set a Fibre Channel address ID on
controllers or a chassis address on Expansion chassis.

Also refer to

“K2 RAID storage description” on page 659

.

Connect the L20 RAID Primary and Expansion chassis

Connect Ethernet, Fibre Channel, and SAS cabling as shown.