beautypg.com

Configuring raid, Configuring raid network and snmp settings – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual

Page 105

background image

September 7, 2007

K2 Storage System Instruction Manual

105

Configuring RAID

Configuring RAID

Use Storage Utility to complete the configuration of the L2 RAID chassis, as
explained in the following topics:

“Configuring RAID network and SNMP settings”

“Binding disk modules”

Refer to

“Prerequisites for initial configuration” on page 100

to confirm that the

RAID storage is ready for configuration.

Configuring RAID network and SNMP settings

Use the Storage Utility to configure the following settings for the Level 2R RAID
chassis:

• IP address

• Subnet mask

• Gateway Address

• SNMP trap destinations

For Level 2R RAID, network and SNMP settings are set and stored on the RAID LAN
card. Therefore the combined RAID storage devices, including the two RAID
controllers and the optional Expansion chassis, is a single entity on the control
network.

The RAID storage device is configured by default for the SNMP community name
“public”. If your site’s policies require using a different SNMP community name,
contact your Grass Valley representative.

To configure these settings, do the following:

1. Launch Storage Utility from the K2 System Configuration application as in the

previous procedure.

2. As prompted, wait while Storage Utility gathers system information, then Storage

Utility opens.

3. In Storage Utility tree view, expand the node for the L2 RAID, right-click the icon

for a L2 RAID controller, and select

Configuration | Network Properties

.

The Controller Network Settings dialog box opens.