Creating a new file system – Grass Valley K2 Storage System Instruction Manual v.3.2 Sep.24 2007 User Manual
Page 110
110
K2 Storage System Instruction Manual
September 7, 2007
Chapter 3 Installing the Level 2R Storage System
g. Close the Progress Report and repeat these steps for other unbound disks. If
specified by your system design, you can bind some disks as Hot Spares, as
explained in
“Binding Hot Spare drives” on page 751
. When you are done, if
you did not bind any extra Hot Spares, you should have the following results:
For Level two redundant storage, on the primary RAID storage chassis you
should have two RAID 1 RANKs of two disks each, one Hot Spare disk, and two
RAID 3 RANK of five disks each. If you have the optional Expansion chassis,
you would have an additional three RAID 3 RANKs of five disks each.
h. Click
Close
in Progress Report window.
4. Restart the K2 Media Server.
NOTE: Make sure start up processes on the K2 Media Server are complete before
proceeding.
5. Continue with the next procedure
Creating a new file system
1. In Storage Utility, click
Tools | Make New File System
. The Setting dialog box
opens.