No preset error, Spi flash error, No preset table – ATEIS IDA8 User Manual
Page 92
![background image](https://www.manualsdir.com/files/772583/content/doc092.png)
ATEIS - IDA8
92
© 2012 ATEÏS
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
1. Update the firmware with the newest version of Ateis Studio.
2. Store a configuration. If the problem is still not solved, please contact your technician.
4.1.7.1.1.6 No Preset Error
Fault Meaning:
There is no configuration inside the device.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
System Fault LED on the front panel of the IDA8C/S.
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display on the touch screen of the IDA8C as:
"No Preset Table"
Also, the text messages display at the [Machine Fault Record] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Store a configuration to the device. If the error is still not solved, please contact your technician.
4.1.7.1.1.7 SPI Flash Error
Fault Meaning:
An internal error of micro controller SPI communication.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up: