Duplex input – ATEIS IDA8 User Manual
Page 492
ATEIS - IDA8
492
© 2012 ATEÏS
This LED lights up if the signal of an input channel is greater than the Overload Thd.
Volume:
The VU-Meter shows the channel RMS level.
Signal:
Indicates if an audio signal presents above -30 dB from the chosen 'Sensitivity'.
Level:
The Signal output level of the channel.
Overload Thd.:
A threshold value to determine the signal of a channel is overloaded or not.
6.9.4
Duplex Input
Component Template:
Component Appearance:
Description:
For AES/EBU input/output, the elements inside the component are very similar to the Input
component except without Sensitivity and Phantom Power. The audio input to the channel 1 of the
board goes to the component Duplex Input A channel 1 & 2, channel 2 to the Duplex Input A
channel 3 & 4, channel 3 to the Duplex Output B channel 1 & 2 and channel 4 to the Duplex Output
B channel 3 & 4.
Control Window: