Mutes or unmutes the module's output.
Matrix Output Mute:
Mutes an input for the output mixing. Different than the Mute element, this element only affects
the output channel itself.
Matrix Output Level:
The attenuation of an input for the output mixing. Different than the Mute element, this element
only affects the output channel itself.
Output Level:
Sets the module's output level.
Threshold:
Sets the threshold for channel activation.
Background Threshold:
Sets how the input signal will be interpreted for opening a gate. The background level will
increase the input activation level.
Hold Time:
Sets the threshold for channel activation.
Attenuation Response Time:
Sets a pre-delay time for automatic attenuation. That means the transition time of the
attenuation when a channel is added or removed.
NOM Attenuation Step:
Sets the amount of attenuation applied each time the number of activated channels increases.
NOM Attenuation Max:
Limits the amount of attenuation applied.
Attenuation Gain:
Indicates the amount of current gain reduction.
Open Mic. Limits:
Chooses the maximum number of simultaneously activated channels.
NOM Attenuation Mode:
Choose this mode if you want a linear attenuation or a logarithmic attenuation be be more
realistic.
Eq1: (NOM-1) x step (same attenuation for each additional channel).
Eq2: log2(NOM) x step.