User define error, Normal/backup amplifier error, Normal/backup amp error – ATEIS IDA8 User Manual
Page 100
ATEIS - IDA8
100
© 2012 ATEÏS
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Update the firmware again.
4.1.7.1.6 User Define Error
Fault Meaning:
A user defined error is detected by the IDA8C/S. This kind of error can be defined by using the
"Fault Definer" DSP component.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of IDA8C/S.
Log:
Text messages display at the touch screen of IDA8C:
"User Define Error"
"XXXXX", where XXXXX is the content defined in "Fault Definer" the DSP component field
[Message].
Text messages display at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Defined on the configuration of the DSP component. Check the component which is the input of
"Fault Definer".
4.1.7.1.7 Normal/Backup Amplifier Error
Fault Meaning:
Amplifier gain is not high enough.
Amplifier gain is too low.
Amplifier has failed.